Medisign MM1000 Blood Glucose Monitoring System
Sh 25,000 Original price was: Sh 25,000.Sh 20,000Current price is: Sh 20,000.
Prescription Might be required at Checkout
| 5 star | 0% | |
| 4 star | 0% | |
| 3 star | 0% | |
| 2 star | 0% | |
| 1 star | 0% |
Sorry, no reviews match your current selections
More Details on This Product
Medisign MM1000 Blood Glucose Monitoring System Take control of your diabetes management with the Medisign MM1000 Blood Glucose Monitoring System. This fast, accurate, and incredibly easy-to-use meter is your reliable partner in tracking blood sugar levels, helping you make informed daily decisions for a healthier life.
Short Description
- Measures blood glucose levels quickly and accurately for daily monitoring.**
- The system requires only a tiny 0.5µL blood sample and uses test strips.**
- Ideal for individuals with diabetes who need simple, reliable tracking.**
Detailed Description
The Medisign MM1000 is designed to make daily blood glucose testing straightforward and stress-free. It provides **quick, reliable results** essential for adjusting diet, exercise, and medication dosages. For customers in Africa and Tanzania, its ease of use and **’NO Coding Required’** feature make it an excellent choice for consistent home monitoring, removing a common point of user error and making the process faster.
Available Product Formulations
The Medisign MM1000 is a **portable electronic medical device (meter)**. It is available as a **complete system kit** which typically includes the meter, a lancing device, lancets, and a supply of test strips. **Replacement Medisign MM1000 Test Strips** are purchased separately.
Uses
The primary use of the Medisign MM1000 Blood Glucose Monitoring System is to **quantitatively measure glucose in fresh capillary whole blood**. This information is vital for the **self-monitoring of blood glucose** by people with diabetes in both Type 1 and Type 2 conditions. Regular monitoring helps to:
- Assess the effectiveness of diabetes management plans (diet, exercise, and medication).
- Identify high (hyperglycemia) and low (hypoglycemia) blood sugar levels quickly.
- Facilitate timely adjustments to insulin or other diabetes medications.
How to Use
•Preparing and Testing
1. Dosage (Testing Frequency):** The frequency of testing depends entirely on your doctor’s recommendation, which is based on your specific diabetes management plan. This may range from once daily to multiple times a day (e.g., before meals, two hours after meals, before bed).
2. Procedure: Wash and dry your hands thoroughly. Insert a test strip into the meter. Use the lancing device to get a small blood sample (0.5µL required). Apply the blood to the strip’s sample area. The meter will display the result in 5 seconds.
3. Duration: This is a long-term monitoring tool to be used for the duration of your diabetes management. The test strips are single-use only.
Side Effects
As the Medisign MM1000 is a monitoring device, it does not cause chemical side effects. However, minor physical discomfort may occur:
Slight Discomfort/Bruising:** Minor pain, temporary bruising, or tenderness at the lancing site (usually the fingertip) is common.
Infection: Although rare, there is a minimal risk of infection if the lancing device or area is not kept clean.
If you experience persistent pain, swelling, or signs of infection at the test site, consult a healthcare provider.
Interactions
The meter does not chemically interact with food or medications. However, certain conditions can affect the **accuracy** of the reading:
- Severe Dehydration: May lead to inaccurate results.
- Hematocrit Levels: Extremely high or low red blood cell volumes can affect the reading.
- Interference: High levels of certain substances like ascorbic acid (Vitamin C) may occasionally interfere with results, though this is rare with modern strips.
Always ensure you are using the correct Medisign MM1000 Test Strips and do not use expired strips. Advise users to consult a doctor if they notice inconsistent results.
Warnings
The Medisign MM1000 system is for in-vitro diagnostic use (outside the body) only and should not be used for the diagnosis of diabetes, only for monitoring. Key safety warnings include:
- Test Strip Handling: Use test strips immediately after removing them from the vial. Tightly seal the vial cap after use to protect remaining strips from humidity.
- Lancet Disposal: Always use a new sterile lancet for each test. Dispose of used lancets safely in a sharps container to prevent accidental needle-stick injuries, particularly important in areas where safe waste disposal is a challenge.
- Operating Conditions: Ensure the meter is used within the specified temperature and humidity range to maintain accuracy.
- Professional Guidance: Never change your medication dosage based solely on a single reading without first consulting your doctor.
A Summary Table of Important Information
| Active Component | Electrochemical (Meter) / Glucose Oxidase (Test Strip) |
| Testing Frequency | As directed by a healthcare professional (usually 1-7 times per day) |
| Result Time | 5 Seconds |
| Sample Volume | 0.5 µL (very small drop of blood) |
| Common Discomfort | Minor prick pain/tenderness at the lancing site. |
| Key Warning | For monitoring only; not for diagnosis of diabetes. Use new lancets for every test. |
How Medisign MM1000 Works
The Medisign MM1000 operates using an electrochemical biosensor method. The test strip contains an enzyme, typically Glucose Oxidase (GOD), and chemical mediators. When the blood sample is applied, the glucose in the blood reacts with the enzyme on the strip. This reaction generates a small electrical current directly proportional to the amount of glucose present in the sample. The meter then measures this current and quickly converts the electrical signal into a digital blood glucose value (displayed in mg/dL or mmol/L) on the screen. The **’NO Coding Required technology means the meter automatically calibrates to the test strip batch, simplifying the process and ensuring measurement accuracy without manual user input error.
Pay How Ever You Want
Â
- Pay via Mobile Money, bank, or card.
- Payments are safe and encrypted.
Delivery Across Tanzania
Delivery Across Tanzania
- We deliver to all regions.
- Orders arrive in 2–4 business days.
- Same-day delivery in Dar es Salaam.
- Free delivery for orders above TZS 250,000.
We Are a Real Pharmacy
Â
- Licensed by the Pharmacy Council of Tanzania.
- All products are genuine.
- Registration can be verified online.
Loging / Register for Bulk Purchase
Login or Register to instantly unlock special wholesale price discounts for eligible products.
Diabetics or
Hypetensive?
- Get Monthly medicine delivery.
- Consumables Discounts.
- Excepts Health Check-ins.
Details
Medisign MM1000 Blood Glucose Monitoring System Take control of your diabetes management with the Medisign MM1000 Blood Glucose Monitoring System. This fast, accurate, and incredibly easy-to-use meter is your reliable partner in tracking blood sugar levels, helping you make informed daily decisions for a healthier life.
Short Description
- Measures blood glucose levels quickly and accurately for daily monitoring.**
- The system requires only a tiny 0.5µL blood sample and uses test strips.**
- Ideal for individuals with diabetes who need simple, reliable tracking.**
Detailed Description
The Medisign MM1000 is designed to make daily blood glucose testing straightforward and stress-free. It provides **quick, reliable results** essential for adjusting diet, exercise, and medication dosages. For customers in Africa and Tanzania, its ease of use and **’NO Coding Required’** feature make it an excellent choice for consistent home monitoring, removing a common point of user error and making the process faster.
Available Product Formulations
The Medisign MM1000 is a **portable electronic medical device (meter)**. It is available as a **complete system kit** which typically includes the meter, a lancing device, lancets, and a supply of test strips. **Replacement Medisign MM1000 Test Strips** are purchased separately.
Uses
The primary use of the Medisign MM1000 Blood Glucose Monitoring System is to **quantitatively measure glucose in fresh capillary whole blood**. This information is vital for the **self-monitoring of blood glucose** by people with diabetes in both Type 1 and Type 2 conditions. Regular monitoring helps to:
- Assess the effectiveness of diabetes management plans (diet, exercise, and medication).
- Identify high (hyperglycemia) and low (hypoglycemia) blood sugar levels quickly.
- Facilitate timely adjustments to insulin or other diabetes medications.
How to Use
•Preparing and Testing
1. Dosage (Testing Frequency):** The frequency of testing depends entirely on your doctor’s recommendation, which is based on your specific diabetes management plan. This may range from once daily to multiple times a day (e.g., before meals, two hours after meals, before bed).
2. Procedure: Wash and dry your hands thoroughly. Insert a test strip into the meter. Use the lancing device to get a small blood sample (0.5µL required). Apply the blood to the strip’s sample area. The meter will display the result in 5 seconds.
3. Duration: This is a long-term monitoring tool to be used for the duration of your diabetes management. The test strips are single-use only.
Side Effects
As the Medisign MM1000 is a monitoring device, it does not cause chemical side effects. However, minor physical discomfort may occur:
Slight Discomfort/Bruising:** Minor pain, temporary bruising, or tenderness at the lancing site (usually the fingertip) is common.
Infection: Although rare, there is a minimal risk of infection if the lancing device or area is not kept clean.
If you experience persistent pain, swelling, or signs of infection at the test site, consult a healthcare provider.
Interactions
The meter does not chemically interact with food or medications. However, certain conditions can affect the **accuracy** of the reading:
- Severe Dehydration: May lead to inaccurate results.
- Hematocrit Levels: Extremely high or low red blood cell volumes can affect the reading.
- Interference: High levels of certain substances like ascorbic acid (Vitamin C) may occasionally interfere with results, though this is rare with modern strips.
Always ensure you are using the correct Medisign MM1000 Test Strips and do not use expired strips. Advise users to consult a doctor if they notice inconsistent results.
Warnings
The Medisign MM1000 system is for in-vitro diagnostic use (outside the body) only and should not be used for the diagnosis of diabetes, only for monitoring. Key safety warnings include:
- Test Strip Handling: Use test strips immediately after removing them from the vial. Tightly seal the vial cap after use to protect remaining strips from humidity.
- Lancet Disposal: Always use a new sterile lancet for each test. Dispose of used lancets safely in a sharps container to prevent accidental needle-stick injuries, particularly important in areas where safe waste disposal is a challenge.
- Operating Conditions: Ensure the meter is used within the specified temperature and humidity range to maintain accuracy.
- Professional Guidance: Never change your medication dosage based solely on a single reading without first consulting your doctor.
A Summary Table of Important Information
| Active Component | Electrochemical (Meter) / Glucose Oxidase (Test Strip) |
| Testing Frequency | As directed by a healthcare professional (usually 1-7 times per day) |
| Result Time | 5 Seconds |
| Sample Volume | 0.5 µL (very small drop of blood) |
| Common Discomfort | Minor prick pain/tenderness at the lancing site. |
| Key Warning | For monitoring only; not for diagnosis of diabetes. Use new lancets for every test. |
How Medisign MM1000 Works
The Medisign MM1000 operates using an electrochemical biosensor method. The test strip contains an enzyme, typically Glucose Oxidase (GOD), and chemical mediators. When the blood sample is applied, the glucose in the blood reacts with the enzyme on the strip. This reaction generates a small electrical current directly proportional to the amount of glucose present in the sample. The meter then measures this current and quickly converts the electrical signal into a digital blood glucose value (displayed in mg/dL or mmol/L) on the screen. The **’NO Coding Required technology means the meter automatically calibrates to the test strip batch, simplifying the process and ensuring measurement accuracy without manual user input error.